When an Oil Top-Up Wasn’t Enough
0-50 MWFailure RiskMain Shaft Bearing

When an Oil Top-Up Wasn’t Enough

Issue

Abnormal behavior was detected in the main shaft bearing temperature readings. Possible root causes included cooling or lubrication system malfunction, high thrust load, inadequate lubricant film generation, or rotor shaft misalignment.

Action

Kavaken identified an upward temperature trend in the main shaft bearing and recommended inspection of the lubrication system.

After the initial oil addition brought no improvement, the site team performed a full lube oil flushing. The bearing temperatures dropped to normal operating levels, confirming that only a complete refresh of the lubrication system could resolve the issue.

Impact

760 MWh production loss prevented